Sicherungskasten: Unterschied zwischen den Versionen
K (Symbolfoto) |
Larsan (Diskussion | Beiträge) (Sicherungsplan ergänzt) |
||
| Zeile 2: | Zeile 2: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
| − | ! Nummer !! | + | ! Nummer !! Typ !! FI !! Verwendung/Beschreibung |
|- | |- | ||
| − | ! colspan=" | + | ! colspan="4" | Oberer Sicherungskasten |
|- | |- | ||
| 1 | | 1 | ||
| − | | rowspan="12" | | + | | rowspan="12" | |
| − | | rowspan="12" | interne Verkabelung | + | | rowspan="12" | |
| + | | rowspan="12" | Reserve (interne Verkabelung) | ||
|- | |- | ||
| 2 | | 2 | ||
| Zeile 33: | Zeile 34: | ||
|- | |- | ||
| 13 | | 13 | ||
| − | | rowspan="2" | | + | | rowspan="2" | 16A/1+FI |
| + | | rowspan="2" | - | ||
| rowspan="2" | Serverschrank (Steckdose), Flurlicht/Notlicht | | rowspan="2" | Serverschrank (Steckdose), Flurlicht/Notlicht | ||
|- | |- | ||
| Zeile 39: | Zeile 41: | ||
|- | |- | ||
| 15 | | 15 | ||
| + | | rowspan="10" | | ||
| + | | rowspan="10" | | ||
| rowspan="10" | Reserve | | rowspan="10" | Reserve | ||
|- | |- | ||
| Zeile 60: | Zeile 64: | ||
|- | |- | ||
| 25 | | 25 | ||
| + | | rowspan="3" | 16A/3 | ||
| + | | rowspan="3" | 1 | ||
| rowspan="3" | Herd | | rowspan="3" | Herd | ||
|- | |- | ||
| Zeile 67: | Zeile 73: | ||
|- | |- | ||
| 28 | | 28 | ||
| − | | | + | | 16A/1 |
| + | | 1 | ||
| + | | Spülmaschine | ||
|- | |- | ||
| 29 | | 29 | ||
| − | | Küche/Bad Steckdosen | + | | 16A/1 |
| + | | 1 | ||
| + | | Küche/Bad Steckdosen, Dunstabzugshaube, Würfel | ||
|- | |- | ||
| 30 | | 30 | ||
| + | | 16A/1 | ||
| + | | 1 | ||
| Küche/Bad Licht | | Küche/Bad Licht | ||
|- | |- | ||
| 31 | | 31 | ||
| + | | 16A/1 | ||
| + | | 1 | ||
| Werkstatt Licht | | Werkstatt Licht | ||
|- | |- | ||
| 32 | | 32 | ||
| + | | 16A/1 | ||
| + | | 1 | ||
| 2-Fach AP-Steckdosen | | 2-Fach AP-Steckdosen | ||
|- | |- | ||
| 33 | | 33 | ||
| + | | rowspan="4" | | ||
| + | | rowspan="4" | | ||
| rowspan="4" | Reserve | | rowspan="4" | Reserve | ||
|- | |- | ||
| Zeile 91: | Zeile 109: | ||
|- | |- | ||
| 37 | | 37 | ||
| + | | rowspan="3" | 16A/3 | ||
| + | | rowspan="3" | 2 | ||
| rowspan="3" | C-Kon Stecker Werkstatt | | rowspan="3" | C-Kon Stecker Werkstatt | ||
| − | |||
|- | |- | ||
| 38 | | 38 | ||
| Zeile 99: | Zeile 118: | ||
|- | |- | ||
| 40 | | 40 | ||
| − | | | + | | 16A/1 |
| + | | 2 | ||
| Kanal Werkstatt 1 | | Kanal Werkstatt 1 | ||
|- | |- | ||
| 41 | | 41 | ||
| + | | 16A/1 | ||
| + | | 2 | ||
| Kanal Werkstatt 2 | | Kanal Werkstatt 2 | ||
|- | |- | ||
| 42 | | 42 | ||
| − | | | + | | 16A/1 |
| + | | 2 | ||
| Kanal Frickelraum 1 | | Kanal Frickelraum 1 | ||
|- | |- | ||
| 43 | | 43 | ||
| + | | 16A/1 | ||
| + | | 2 | ||
| Kanal Frickelraum 2 | | Kanal Frickelraum 2 | ||
|- | |- | ||
| 44 | | 44 | ||
| − | | | + | | 16A/1 |
| + | | 2 | ||
| Kanal Chillraum 1 | | Kanal Chillraum 1 | ||
|- | |- | ||
| 45 | | 45 | ||
| + | | 16A/1 | ||
| + | | 2 | ||
| Kanal Chillraum 2 | | Kanal Chillraum 2 | ||
|- | |- | ||
| 46 | | 46 | ||
| + | | 16A/1 | ||
| + | | 2 | ||
| 2-fach AP-Steckdose Chillraum | | 2-fach AP-Steckdose Chillraum | ||
|- | |- | ||
| 47 | | 47 | ||
| + | | 16A/1 | ||
| + | | 2 | ||
| Chillraum und Flur Licht | | Chillraum und Flur Licht | ||
|- | |- | ||
| 48 | | 48 | ||
| + | | | ||
| + | | | ||
| Stromstoßautomat | | Stromstoßautomat | ||
|- | |- | ||
| − | ! colspan=" | + | ! colspan="4" | Unterer Sicherungskasten |
|- | |- | ||
| 1 | | 1 | ||
| − | | rowspan="4" | Unser Zähler | + | | rowspan="4" | Swissnox SX-3M |
| + | | rowspan="4" | 1+2 | ||
| + | | rowspan="4" | [[SmartMeter|Unser Zähler]] | ||
|- | |- | ||
| 2 | | 2 | ||
| Zeile 140: | Zeile 176: | ||
|- | |- | ||
| 5 | | 5 | ||
| + | | rowspan="5" | ? | ||
| + | | rowspan="5" | ? | ||
| rowspan="5" | Neozed-Element Durchlauferhitzer | | rowspan="5" | Neozed-Element Durchlauferhitzer | ||
|- | |- | ||
| Zeile 151: | Zeile 189: | ||
|- | |- | ||
| 10 | | 10 | ||
| + | | rowspan="3" | | ||
| rowspan="3" | | | rowspan="3" | | ||
| rowspan="3" | interne Verkabelung? | | rowspan="3" | interne Verkabelung? | ||
| Zeile 159: | Zeile 198: | ||
|- | |- | ||
| 13 | | 13 | ||
| + | | rowspan="5" | ? | ||
| + | | rowspan="5" | 1+2 | ||
| rowspan="5" | Hauptschalter | | rowspan="5" | Hauptschalter | ||
|- | |- | ||
| Zeile 170: | Zeile 211: | ||
|- | |- | ||
| 18 | | 18 | ||
| + | | rowspan="4" | ? | ||
| + | | rowspan="4" | 1 | ||
| rowspan="4" | 4-Polig FI | | rowspan="4" | 4-Polig FI | ||
|- | |- | ||
| Zeile 179: | Zeile 222: | ||
|- | |- | ||
| 22 | | 22 | ||
| + | | rowspan="4" | ? | ||
| + | | rowspan="4" | 2 | ||
| rowspan="4" | 4-Polig FI | | rowspan="4" | 4-Polig FI | ||
|- | |- | ||
| Zeile 187: | Zeile 232: | ||
| (25) | | (25) | ||
|- | |- | ||
| − | ! Nummer !! | + | ! Nummer !! Typ !! FI !! Verwendung/Beschreibung |
|} | |} | ||
Version vom 10. November 2016, 19:39 Uhr
| Nummer | Typ | FI | Verwendung/Beschreibung |
|---|---|---|---|
| Oberer Sicherungskasten | |||
| 1 | Reserve (interne Verkabelung) | ||
| 2 | |||
| 3 | |||
| 4 | |||
| 5 | |||
| 6 | |||
| 7 | |||
| 8 | |||
| 9 | |||
| 10 | |||
| 11 | |||
| 12 | |||
| 13 | 16A/1+FI | - | Serverschrank (Steckdose), Flurlicht/Notlicht |
| 14 | |||
| 15 | Reserve | ||
| 16 | |||
| 17 | |||
| 18 | |||
| 19 | |||
| 20 | |||
| 21 | |||
| 22 | |||
| 23 | |||
| 24 | |||
| 25 | 16A/3 | 1 | Herd |
| 26 | |||
| 27 | |||
| 28 | 16A/1 | 1 | Spülmaschine |
| 29 | 16A/1 | 1 | Küche/Bad Steckdosen, Dunstabzugshaube, Würfel |
| 30 | 16A/1 | 1 | Küche/Bad Licht |
| 31 | 16A/1 | 1 | Werkstatt Licht |
| 32 | 16A/1 | 1 | 2-Fach AP-Steckdosen |
| 33 | Reserve | ||
| 34 | |||
| 35 | |||
| 36 | |||
| 37 | 16A/3 | 2 | C-Kon Stecker Werkstatt |
| 38 | |||
| 39 | |||
| 40 | 16A/1 | 2 | Kanal Werkstatt 1 |
| 41 | 16A/1 | 2 | Kanal Werkstatt 2 |
| 42 | 16A/1 | 2 | Kanal Frickelraum 1 |
| 43 | 16A/1 | 2 | Kanal Frickelraum 2 |
| 44 | 16A/1 | 2 | Kanal Chillraum 1 |
| 45 | 16A/1 | 2 | Kanal Chillraum 2 |
| 46 | 16A/1 | 2 | 2-fach AP-Steckdose Chillraum |
| 47 | 16A/1 | 2 | Chillraum und Flur Licht |
| 48 | Stromstoßautomat | ||
| Unterer Sicherungskasten | |||
| 1 | Swissnox SX-3M | 1+2 | Unser Zähler |
| 2 | |||
| 3 | |||
| 4 | |||
| 5 | ? | ? | Neozed-Element Durchlauferhitzer |
| 6 | |||
| 7 | |||
| 8 | |||
| 9 | |||
| 10 | interne Verkabelung? | ||
| 11 | |||
| 12 | |||
| 13 | ? | 1+2 | Hauptschalter |
| 14 | |||
| 15 | |||
| 16 | |||
| 17 | |||
| 18 | ? | 1 | 4-Polig FI |
| 19 | |||
| 20 | |||
| 21 | |||
| 22 | ? | 2 | 4-Polig FI |
| 23 | |||
| 24 | |||
| (25) | |||
| Nummer | Typ | FI | Verwendung/Beschreibung |